nanog mailing list archives

Re: Question about normal ops - BGP Flaps nightly


From: Christopher Morrow <morrowc.lists () gmail com>
Date: Fri, 22 Nov 2019 08:20:07 +0800

On Fri, Nov 22, 2019 at 12:54 AM Tom Beecher <beecher () beecher cc> wrote:

I agree that this sounds like an automated process in some way.

I would suspect that either a vendor code update changed something such that a given command that would not cause 
session reset now does, or they changed their automation to include a command that would cause a reset without 
realizing it/slipped through the cracks / etc.


thanks to some private chat with another nanog participant it was
noted the reason for failure is:
  "Error event Operation timed out(60) for I/O session - closing it"

This is fine, I suppose, except that I have v4/v6 sessions on the same
ptp link/path. So, if v6 times out I'd have expected v4 to also
timeout.
Strangely I had thought we were told the 2 links we have land on 2
different devices, but router-id tells me that's false as well. :(
The sessions appear to reset on both devices (according to syslog) at
the same time, I had thought (because our alerter is telling me) the
sessions had a gap between the 2 drops.

The physical payer is some bidi fiber path across an L2 (ether)
network to the provider, perhaps the problem isn't on the l3/bgp parts
here, but in the l2 network between. we are at the end of our time
here so I think I'll gather some logs and see if the provider can make
sense of the issues.

On Thu, Nov 21, 2019 at 9:18 AM Mel Beckman <mel () beckman org> wrote:

No. There should be no reason to bounce the session. Do you have soft updates turn on?

-mel via cell

On Nov 21, 2019, at 1:46 AM, Christopher Morrow <morrowc.lists () gmail com> wrote:

Howdy!
A question of interest to me, currently, is whether it's normal for
providers to cause BGP flaps to their customers nightly... This seems,
in my case, to be the provider PROBABLY updating prefix-filters on my
session(s).

Particularly AS56554 is currently getting v4/v6 transit from 2
providers, one of which we have 2 links toward. That provider appears
to flap both of our ipv6 (only) bgp peers each night at about the same
time each night. This smells like: "filter updates', but something
that's different than the v4 filter update? (or perhaps they have no
v4 filtering to update?)

In the end, should customers expect nightly (or on a regular cadence)
to see their sessions bounce? It hasn't been my experience in other
situations...

-chris