Re: MX204 Virtual Chassis Setup


From: Mark Tinka <mark@tinka.africa>
Date: Wed, 23 Aug 2023 18:40:06 +0200



On 8/23/23 18:29, tim () pelican org wrote:

Not Trio, and different PLM :)

Yes, aware... I was just speaking in general for what is likely to be a very popular platform :-).


MX304 (well, strictly LMIC16) has the same restriction, and a need for another entry in the magic port checker 
(https://apps.juniper.net/home/port-checker/index.html) for restrictions beyond "SUM(port-speeds) <= 1.6T".

Yep.

That trick they did where you can live with one RE and get 3 MIC's in the MX304 is... well, I guess everyone will have their own opinion.


They make sense once you've looked at the block diagram for the thing and followed the lines, but things like "4x10G 
breakout can only go in odd-numbered ports, and you have to leave the corresponding next-lowest even-numbered port empty" are not 
instantly obvious.

They do take some getting used to. But this is what comes with all the flexibility operators often seek.