nanog mailing list archives
Re: Brocade Fabric Help
From: TJ McCleve <tmccleve () voonami com>
Date: Thu, 30 Jun 2016 21:28:10 +0000
I would suggest opening a TAC to get the full details on why it’s happening if the root cause not readily apparent. Typically remediating a these types of mismatches entails copying the default config to startup (triggers a reload) and rejoining the fabric. On 6/30/16, 1:41 PM, "NANOG on behalf of Mike Hammett" <nanog-bounces () nanog org on behalf of nanog () ics-il net> wrote:
I asked on the Brocade forum, but it's largely been crickets there. I hoped someone here would have an idea. One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary) The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary) I saw that means, "The DCM Configuration DB is different on both the ends of ISL," but I have no idea how to resolve that. VDX-6720s running 4.1.3b. ----- Mike Hammett Intelligent Computing Solutions http://www.ics-il.com Midwest Internet Exchange http://www.midwest-ix.com
Current thread:
- Brocade Fabric Help Mike Hammett (Jun 30)
- Re: Brocade Fabric Help Youssef Bengelloun-Zahr (Jun 30)
- Re: Brocade Fabric Help Fred Hollis (Jun 30)
- Re: Brocade Fabric Help TJ McCleve (Jun 30)