nanog mailing list archives

Re: Brocade Fabric Help


From: TJ McCleve <tmccleve () voonami com>
Date: Thu, 30 Jun 2016 21:28:10 +0000

I would suggest opening a TAC to get the full details on why it’s happening if the root cause not readily apparent. 
Typically remediating a these types of mismatches entails copying the default config to startup (triggers a reload) and 
rejoining the fabric.
        
On 6/30/16, 1:41 PM, "NANOG on behalf of Mike Hammett" <nanog-bounces () nanog org on behalf of nanog () ics-il net> 
wrote:

I asked on the Brocade forum, but it's largely been crickets there. I hoped someone here would have an idea. 

One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary) 
The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary) 

I saw that means, "The DCM Configuration DB is different on both the ends of ISL," but I have no idea how to resolve 
that. 


VDX-6720s running 4.1.3b. 




----- 
Mike Hammett 
Intelligent Computing Solutions 
http://www.ics-il.com 



Midwest Internet Exchange 
http://www.midwest-ix.com 