On Sun, Sep 10, 2017 at 10:47:05AM +0100, Nick Hilliard wrote:
Baldur Norddahl wrote:
Loopback interfaces should be configured as /128. How you allocate these do
not matter.

..so long as there are interface ACLs on your network edge which block
direct IP access to these IP addresses.

or, maybe even more efficient, assign all loopbacks from a dedicated netblock which you null-route on the edge/your 
border devices.