Re: Temp at Level 3 data centers
From: Sam Silvester <sam.silvester () gmail com>
Date: Thu, 12 Oct 2017 10:22:31 +1030
On Thu, Oct 12, 2017 at 3:39 AM, Naslund, Steve <SNaslund () medline com> wrote:
If the ambient temperature is higher is means the temperatures throughout the device would be higher and the temp at those points is what really matters. I would also be concerned because if they lose one of the a/c units what would the ambient temperature rise to? I would want them to tell me what the set point of the a/c actually is. Bottom line 80 F input air is too hot in my opinion and apparently the equipment's opinion as well.
My quick thoughts on the matter: 1. Above all else, know what your DC provider states in their SLA/contract. 2. It's never a bad idea to try to be on the best possible personal terms with the DC manager(s), the better you get along the more they're inclined to share knowledge/issues and work with you on any concerns. 3. You can't infer faults or lack of redundancy from the running temperature - by way of example several facilities I know run at 25 degrees celsius but if a chilled water unit in a given data hall fails there's a number of DX units held in standby to take over. This is where point 2 comes in handy as knowing somebody on the ground they'll often be quite happy to run through failure scenarios with you and help make sure everybody is happy with the risk mitigation strategy. Out of idle curiosity - I'm curious as to if the equipment that is alarming is configurable or not? Reason I ask is I've heard users claiming environmental parameters were out of spec before, but then it turned out it was their own environmental monitoring they'd installed in the rack (using default parameters out of the box, not configured to match the facility SLA) that was complaining about a set point of 25... Cheers, Sam
Current thread:
- Re: Temp at Level 3 data centers, (continued)
- Re: Temp at Level 3 data centers Ken Chase (Oct 11)
- Re: Temp at Level 3 data centers Zachary Winnerman (Oct 11)
- Re: Temp at Level 3 data centers Josh Reynolds (Oct 11)
- Re: Temp at Level 3 data centers Leo Bicknell (Oct 11)
- Re: Temp at Level 3 data centers Eric Kuhnke (Oct 11)
- Message not available
- Re: Temp at Level 3 data centers Zachary Winnerman (Oct 11)
- Re: Temp at Level 3 data centers Ken Chase (Oct 11)
- RE: Temp at Level 3 data centers Naslund, Steve (Oct 11)
- Re: Temp at Level 3 data centers Jeremy Austin (Oct 11)
- Re: Temp at Level 3 data centers Thomas Bellman (Oct 11)
- Re: Temp at Level 3 data centers Sam Silvester (Oct 12)
- Re: Temp at Level 3 data centers Jean-Francois Mezei (Oct 12)
- Re: Temp at Level 3 data centers bzs (Oct 13)
- Re: Temp at Level 3 data centers Chris Adams (Oct 13)
- Re: Temp at Level 3 data centers Roy (Oct 13)
- Re: Temp at Level 3 data centers Jean-Francois Mezei (Oct 13)
- Re: Temp at Level 3 data centers Roy (Oct 13)
- RE: Temp at Level 3 data centers Naslund, Steve (Oct 11)
- Re: Temp at Level 3 data centers Chuck Anderson (Oct 11)