nanog mailing list archives

Re: MAE-EAST Moving? from Tysons corner to reston VA.


From: John Fraizer <nanog () EnterZone Net>
Date: Fri, 16 Jun 2000 13:14:41 -0400 (EDT)



I spoke with HP today.  Their Procurve series switches support a maximum
of 1522 bytes to include 802.1Q tagging.  They wouldn't discuss if they
planned to join the rest of the world in supporting jumbo frames on GigE.

---
John Fraizer
EnterZone, Inc


On Fri, 16 Jun 2000, Mikael Abrahamsson wrote:


On 16 Jun 2000 michael.dillon () gtsip net wrote:

What is the largest MTU that you can use across a GigE fabric?

Frmo Extreme Networks manual:

The jumbo_frame_mtu range is 1523 to 9216. The value describes the maximum
size "on the wire," and includes 4 bytes of CRC plus another 4 bytes if
802.1Q tagging is being used.

I'd be surprised if other vendors are much different.

-- 
Mikael Abrahamsson    email: swmike () swm pp se








Current thread: