Bugtraq mailing list archives

Re: Default password in Bay Networks switches.


From: obrecht () IEM RWTH-AACHEN DE (Rolf Obrecht)
Date: Fri, 12 Mar 1999 12:37:56 +0100


On Thu, 11 Mar 1999, Igor Sviridov wrote:

On Wed, Mar 10, 1999 at 02:48:58PM -0800, Jan B. Koum wrote:

    Ok.. so you would think after 3Com $%#& up last year of inserting
    default password into firmware vendors would learn their lesson?
    [See http://geek-girl.com/bugtraq/1998_2/0340.html for 3com rant]

    Hah! Welcome to the world of strings and Bay Networks firmware
    files. I have looked at some bay networks switches and see that
    the following have default password of "NetICs"

BayStack 350T   HW:RevC  FW:V1.01 SW:V1.2.0.10
BayStack 350T   HW:RevC  FW:V1.01 SW:V2.0.0.15

Also works on:

BayStack 350T-HD HW:RevA  FW:V1.03 SW:V2.0.2.1        (24 port)
BayStack 350T    HW:RevC  FW:V1.00 SW:V2.0.2.1        (16 port)

Does not work on:

BayStack 450-24T HW:RevB  FW:V1.04 SW:V1.0.1.0

-- Yan

--igor

Also works on

BayStack 350T HW:RevC  FW:V1.01 SW:V1.03 (16port)

Rolf

---
Rolf Obrecht                    RWTH Aachen
Tel. +49 241 807646             Institut fuer Elektrische Maschinen
Fax  +49 241 8888270            Schinkelstrasse 4, D-52056 Aachen