Mark,

But you said “Gas-fired furnaces or heaters should not have an impact
because the only electrical requirement is to fire up the pilot light.”
There is no gas-fired furnace I know of that doesn’t require a blower fan.
How else does the heat get out of the furnace?

To answer your question, you need to understand that this safety system
has two components. The first component, the furnace interlock relay, is
designed to interlock the blower with the forced-air system, which also
includes an outside air supply valve. When the blower is energized, a
circuit inside the furnace gets power. The blower and furnace operate
continuously when this circuit is energized, and the supply valve opens and
closes as needed to ensure the air doesn’t get stale.

The safety second component is the limit switch, which primarily turns the
blower fan on and off, but also has a safety role. When the temperature in
the air supply plenum gets too hot, the limit switch turns off the furnace
burner (or boiler, in a water-based system) to prevent damage, and possibly
a fire, from overheating.

The actual state mechanics are thus not as simple as “if the blower fails
the furnace won’t light”. And it’s because of these complex state mechanics
that furnace electricity is hard wired.

Without AC power, no furnace can operate in a power outage. So that’s
certainly not “no impact” from a utility failure. But the many thousands of
deaths that occurred in homes and offices before these safety systems were
put into the code is why you need a generator transfer switch if you want
heat (or A/C) in your home during an outage.

 -mel

On Aug 31, 2021, at 7:15 AM, Mark Tinka <mark@tinka.africa> wrote:



On 8/31/21 16:06, Mel Beckman wrote:

I think you’re forgetting about the all-important blower fan in a
gas-fired furnace.

Well, I was referring to a pure electric furnace, not one that uses a
blower over a gas-fired one :-).

In that case, the blower is not a major draw on power.

But again, we don't have those things here, so :-).


That said, the reason the code requires furnaces to be hardwired is to
ensure that the blower interlock system can’t be bypassed. An electrical
interlock ties a heat recover ventilator to circulation air blower
operation of a forced-air furnace system. This ensure that the blower
circulates supply and return air within the structure. A plug-in power
source leads to the possibility that this interlock could be accidentally
defeated, resulting in an overheat within the flame box.

Makes sense.

Does this, then, mean that if the blower itself were to fail, the gas
burner would not light?

Mark.