Re: MPLS in the campus Network?


From: Mark Tinka <mark.tinka () seacom mu>
Date: Fri, 21 Oct 2016 18:44:38 +0200



On 21/Oct/16 16:19, Marian Ďurkovič wrote:


Much easier to setup, operate & maintain than MPLS and obviously much
lower cost. Based on 6-months production experience, my recommendation
would be to stay away from MPLS in the campus.

I'd be curious to hear what MPLS-specific issues you faced in the 6
months you had to operate such a network.

Been running IP/MPLS Core, Edge and Access networks for over 15 years,
and apart from bugs which affect any protocol or feature implementation,
I can't say it has been a nightmare to operate to the point of not
recommending it.

I have far fewer words to say about STP, although - I'll admit - I've
never run TRILL.

Mark.