Just to throw it out there but I always try not to use RED cable.
Normally, RED wire in any building is dedicated as FIRE system cabling.


Curtis Starnes
Senior Network Administrator
Granbury ISD
600 W. Bridge St. Ste. 40
Granbury, Texas  76048
(817) 408-4104
(817) 408-4126 Fax
curtis.starnes () granburyisd org
www.granburyisd.org 
 
 

OPEN RECORDS NOTICE: This email and responses may be subject to Texas Open Records laws and may be disclosed to the 
public upon request. 



-----Original Message-----
From: NANOG [mailto:nanog-bounces () nanog org] On Behalf Of Owen DeLong
Sent: Sunday, March 13, 2016 7:10 PM
To: Yardiel Fuentes <yardiel () gmail com>
Cc: nanog () nanog org
Subject: Re: DataCenter color-coding cabling schema

I don’t know of any universal standards, but I’ve used the following in several installatins I was responsible for to 
good avail:

Twisted Pair:

RED:    Untrusted Network (Internet or possibly DMZ)
YELLOW: Optional for DMZ networks though I preferred to avoid documented in [1] below
BLUE:   Trusted Network (back-end, internal, etc.)
GREEN:  RS-232 straight-thru
PURPLE: RS-232 X-Over (effectively Null Modem) 12345678 <-> 87654321 pin map.
ORANGE: Ethernet X-Over (Best avoided documented in [2] below)
GREY:   Special purpose cabling not in one of the above categories

Fiber:
Orange — Multimode Fiber
Yellow — Singlemode Fiber

The absolute most useful thing you can do if you can impose the discipline to update the cable map rigorously and/or 
allocate manpower for periodic audits is to apply a unique serial number to each cable. I preferred to document not 
only the cable ID, but also the length. For the installations where I have worked, 5 digits was sufficient unique ID, 
so I used formats like IIIII-L[.L] where IIIII was a unique ID and L.L was the length of the cable in feet. (e.g. 
00123-6.5 is cable number 123 which is 6.5 feet in length).

The labels are (ideally) the self-laminating wrap-around types. I prefer the Brady labeling system which will 
automatically print 2-4 (depending on font size) instances of the label text on the self-laminating label such that it 
can be read from virtually any side of the cable without requiring you to rotate the label into view in most cases.

The Brady labeling system is a bit overpriced compared to the Brother P-Touch, but the expanded capabilities and the 
quality of the label adhesives and such is, IMHO, sufficiently superior to justify the cost.

Whatever you do, please do not use Flag labels on cables… I HATE THEM. They are a constant source of entanglement and 
snags. They often get knocked off as a result or mangled beyond recognition, rendering them useless.

Similarly, I’ve found that circuit-ID and end-point labels on cables are often ill-maintained, so if you do use them, 
please make sure you remove them when the cable is moved/removed.

The length is very useful because it gives you a radius within which the other end of the cable must be located and you 
can usually expect it to be reasonably close to the outer edge of that radius.

More than a few times I’ve prevented a serious outage by giving the port number to the remote hands guy and then 
insisting that he read me the cable ID. “No, try the other port FE-0/2/4… You’re off by one. It’s 
above/left/right/below you.”

[1] I prefer to avoid Yellow cables because some people have trouble understanding that Yellow Fiber and Yellow UTP 
might have different meanings. I also feel that the distinction between UNTRUSTED and DMZ networks is usually not all 
that important in most cabling situations. YMMV.

[2] In this era of Auto-MDI/MDI-X ports and the like, it’s very rare to encounter a situation that truly requires a 
crossover cable with no viable alternative. If such is needed, I prefer to document it on the cable tags rather than 
using a special color code. Again, you have the risk of people not understanding that orange Fiber might not mean what 
Orange copper means. YMMV

Yes, I know you can now get virtually any type of fiber in virtually any color, but the simple fact of the matter 
remains that when you send skippy out to buy emergency jumpers or such, you’re most likely going to either get orange 
multimode or yellow singlemode and that’s just the way it is.

Owen

On Mar 12, 2016, at 11:11 , Yardiel Fuentes <yardiel () gmail com> wrote:

Hello Nanog-ers,

Have any of you had the option or; conversely, do you know of “best 
practices" or “common standards”,  to color code physical cabling for 
your connections in DataCenters for Base-T and FX connections? If so, 
Could you share  any ttype of color-coding schema you are aware of ?…. 
Yes, this is actually considering paying for customized color-coded 
cabling in a Data Center...

Mr. Google did not really provide me with relevant answers on the 
above… beyond the typical (Orange is for MMF, yellow for SMF, etc)…

Any reasons for or against it welcome too...

--