Re: BCP38 dismissal


From: "Paul Wall" <pauldotwall () gmail com>
Date: Fri, 5 Sep 2008 11:46:29 -0400

On Thu, Sep 4, 2008 at 2:12 PM, Greg Hankins <ghankins () mindspring com> wrote:
Hey Paul, would you be able to demonstrate this problem?  I'd like to see
it so that we can investigate and fix it.

You are correct that the first generation of E-Series hardware (EtherScale)
had little control plane protection.

The current E-Series hardware (TeraScale) has a completely different
architecture that rate limits, queues and filters all packets destined to
the control plane.

In my current job, I don't have access to this kind of iron.  The
afforementioned Linksys solution provides more than enough capacity.

If you could provide me login/enable access to a current E-series box
with no firewalls sitting in front, I can most likely replicate.

(Off-list, in the interest of keeping things on-topic, with a
follow-up summary sent on-...)

Drive Slow,
Paul Wall


Current thread: