Well, you really cannot get away from the single point of failure if the leased lines are from the same ISP, unless they are offering you 2 different POP's on different grids. If it is two different ISP's, I would still be surprised if they are not on the same power grid, but better scenario. The two WIC modules reduce the cost and the point in getting two leased lines. Your more common points of failure are going to be an ISP, which the two WIC's work, Local Power, which two WIC's or Two routers don't work and does not matter, Hardware Failure, most common and now nothing works. If a router, module, fan, etc fails it is better to have a backup. You will have to run a routing protocol to get real redundancy, having weighted static routes to switch traffic to the backup ISP, or put a manual route change in to work when you need the backup for the two ISP scenario. Always give yourself as much redundancy as you can afford.
Thank You, Chris Myers clmmacunix () charter net John 1:17For the Law was given through Moses; grace and truth were realized through Jesus Christ.
Go Vols!!!! On Apr 13, 2008, at 3:18 PM, shadow floating wrote:
Hi guys, my company is having 2 leased lines internet connections and they were about to buy two routers to make them standby to each other, each with one of the internet connections, as they were discussing with some network consultant...he convinced them to reduce cost and put 2 wics in one router only each connected to the each internet connection instead of buying 2 routers....is that appropriate?? thanks alot Nad _______________________________________________ firewall-wizards mailing list firewall-wizards () listserv icsalabs com https://listserv.icsalabs.com/mailman/listinfo/firewall-wizards
_______________________________________________ firewall-wizards mailing list firewall-wizards () listserv icsalabs com https://listserv.icsalabs.com/mailman/listinfo/firewall-wizards
Current thread:
- router with 2 redundant inferfaces shadow floating (Apr 15)
- Re: router with 2 redundant inferfaces Fetch, Brandon (Apr 17)
- Re: router with 2 redundant inferfaces Chris Myers (Apr 17)
- Re: router with 2 redundant inferfaces Darden, Patrick S. (Apr 17)
- Re: router with 2 redundant inferfaces kevin horvath (Apr 17)
- Re: router with 2 redundant inferfaces Prabhu Gurumurthy (Apr 17)
- Re: router with 2 redundant inferfaces pkc_mls (Apr 17)
- Re: router with 2 redundant inferfaces Razeor (Apr 17)
- Re: router with 2 redundant inferfaces Paul D. Robertson (Apr 17)
- Re: router with 2 redundant inferfaces Vladimir Vitkov (Apr 21)
- Re: router with 2 redundant inferfaces shadow floating (Apr 21)
- Re: router with 2 redundant interfaces Richard Golodner (Apr 22)
- Re: router with 2 redundant interfaces Dave Piscitello (Apr 24)