Bugtraq mailing list archives

Re: Security Bug in Bintec Router Firmware (CLID)


From: p () ZNET DE (Pascal Gienger)
Date: Fri, 12 Feb 1999 08:55:05 +0100


On Thu, Feb 11, 1999 at 01:19:16PM +0100, Thomas Schmidt wrote:

From firmware revision BOSS V4.8 Release 1, the user could select
if the screening indicator is verified and specify the expected value.
This can be done for every indiviual number, and is selected by
modification of the SNMP configurationtable "dialtable".

But this still leaves the hole of the same incoming number of
possible international and national calls open....
The screening was only one thing (and I corrected this in my routers'
setup, thanks to Mr Schmidt!). The other thing is the same incoming
number for (e.g.) +41 1 1234567 and +49 411 1234567, resulting
both in 4111234567.
The "numbering type" field is not looked at. ;-) "Numbering plan" should
always be ISDN for non-modem connections...

It would be nice if that would be integrated in the future releases
of the firmware.

Pascal
--
Unix,   Pascal Gienger, Moosstr. 7 /\ 7 .rtssooM ,regneiG lacsaP    xinU
Networx 78467 Konstanz, p () znet de /  \ ed.tenz@p ,znatsnoK 76487 xrowteN
& WWW       http://pascal.znet.de/    \ed.tenz.lacsap\\:ptth       WWW &
        http://echo.znet.de:8888/ echo \8888:ed.tenz.ohce\\:ptth



Current thread: