Re: VoIP and HFA Siemens
From: Martin Visser <martinvisser99 () gmail com>
Date: Fri, 2 Jul 2010 08:13:40 +1000
Giuseppe, Clearly if you did your capture of normal VOIP conversations, your capture is inadequate. However you have not provided enough information for us to help you. We would need to know * How you performed the capture? Did you use port-mirroring, or did you use filters (possibly incorrectly). * What is the network topology (were there multiple interfaces connected to the interface, meaning that your capture tool only saw traffic going on one of the interfaces and one direction?). This could apply to any switch our router in the path, depending on where you did the capture. Regards, Martin MartinVisser99 () gmail com On Thu, Jul 1, 2010 at 5:11 PM, Giuseppe Montanarella < giuseppe.montanarella () gmail com> wrote:
Hi all, I have the problem to analyse the VoIP traffic from Siemens PBX, when I make a trace a see RTP traffic between PBX and the phone in one way only. Bye Giuseppe ___________________________________________________________________________ Sent via: Wireshark-users mailing list <wireshark-users () wireshark org> Archives: http://www.wireshark.org/lists/wireshark-users Unsubscribe: https://wireshark.org/mailman/options/wireshark-users mailto:wireshark-users-request () wireshark org ?subject=unsubscribe
___________________________________________________________________________ Sent via: Wireshark-users mailing list <wireshark-users () wireshark org> Archives: http://www.wireshark.org/lists/wireshark-users Unsubscribe: https://wireshark.org/mailman/options/wireshark-users mailto:wireshark-users-request () wireshark org?subject=unsubscribe
Current thread:
- VoIP and HFA Siemens Giuseppe Montanarella (Jul 01)
- Re: VoIP and HFA Siemens Martin Visser (Jul 01)