nanog mailing list archives

Re: GPS Sync Outage


From: "Forrest Christian (List Account)" <lists () packetflux com>
Date: Mon, 6 Jan 2020 09:00:59 -0800

Over the weekend, tests confirmed that all of these issues are related to a
end of the year GLONASS day rollover bug in the GNSS receiver.  A power
cycle seems to correct it until the next rollover in 2024.

 If you're still seeing these issues then power cycle the device using a
method appropriate to the device.  On the RackInjector in particular there
is a power control button on the GNSS statusimulation screen.

On Mon, Jan 6, 2020, 8:50 AM Bryton Herdes <bherdes () myjec coop> wrote:

Matt,

I saw a similar issue today with Cambium PMP450i’s losing sync from our
PacketFlux rack injectors. May not be useful information to you know
considering there’s chatter about this already on social media.

Thanks,

Bryton J. Herdes
Network Engineer
Jackson Electric Cooperative
100 Cooperative Way
Bay City, TX 77414


Confidentiality Notice: This e-mail message, including any attachments, is
 for the sole use of the intended recipient(s) and may contain
confidential and privileged information. Any unauthorized review, copy,
use, disclosure, or distribution is prohibited. If you are not the
intended recipient, please contact the sender by reply e-mail and destroy
all copies of the original message.

On Dec 31, 2019, at 4:08 PM, Matt Hoppes <
mattlists () rivervalleyinternet net> wrote:

Is anyone else seeing GPS timing source outages across the U. S. In the
last two hours?