nanog mailing list archives

Re: DWDM Mux/Demux using 40G Optics


From: Colton Conor <colton.conor () gmail com>
Date: Mon, 19 Jun 2017 14:30:37 -0500

I guess that is the real question. Besides the client ports that are
clearly identified by channel number on Muxes, what channels can the
special ports handle?

http://www.fs.com/products/43723.html It has 4 special service port options:

1. Expansion Port (Based on what I am seeing, I think this would be to
stack another mux if you needed more channels. So I assume it allows all
channels to be added besides the client channels?)
2. Monitor Port (I think this is just a tap that you would hook a monitor
up to, and be able to see all channels coming through with a meter. I
assume not a good idea to add/drop channels through this port)?
3. 1310nm Port (Labeled as 1310, but clearly allows more than just 1310
since tutorial is saying it supports QSFP+ which is 1270 - 1330 nm, so what
range does it really support or is there no a range?)
4. 1550nm Port (Labeled as 1550nm, but I wonder if its like the 1330nm?)


Would you recommend a monitor port on every mux you buy?



On Mon, Jun 19, 2017 at 2:18 PM, Mike Hammett <nanog () ics-il net> wrote:

Verify pass-through frequencies for the 1310 (or equivalent) for the
passive mux in question. This would only work for a single channel.



-----
Mike Hammett
Intelligent Computing Solutions
http://www.ics-il.com

Midwest-IX
http://www.midwest-ix.com

------------------------------
*From: *"Luke Guillory" <lguillory () reservetele com>
*To: *"Faisal Imtiaz" <faisal () snappytelecom net>, "Colton Conor" <
colton.conor () gmail com>
*Cc: *"nanog list" <nanog () nanog org>
*Sent: *Monday, June 19, 2017 2:13:10 PM
*Subject: *RE: DWDM Mux/Demux using 40G Optics


Faisal,

How would he inject his current 4x10 40g into the mux which is currently
on a single LC cable?





Luke Guillory
Network Operations Manager

Tel:    985.536.1212 <(985)%20536-1212>
Fax:    985.536.0300 <(985)%20536-0300>
Email:  lguillory () reservetele com

Reserve Telecommunications
100 RTC Dr
Reserve, LA 70084

____________________________________________________________
_____________________________________

Disclaimer:
The information transmitted, including attachments, is intended only for
the person(s) or entity to which it is addressed and may contain
confidential and/or privileged material which should not disseminate,
distribute or be copied. Please notify Luke Guillory immediately by e-mail
if you have received this e-mail by mistake and delete this e-mail from
your system. E-mail transmission cannot be guaranteed to be secure or
error-free as information could be intercepted, corrupted, lost, destroyed,
arrive late or incomplete, or contain viruses. Luke Guillory therefore does
not accept liability for any errors or omissions in the contents of this
message, which arise as a result of e-mail transmission. .

-----Original Message-----
From: NANOG [mailto:nanog-bounces () nanog org] On Behalf Of Faisal Imtiaz
Sent: Monday, June 19, 2017 2:02 PM
To: Colton Conor
Cc: nanog list
Subject: Re: DWDM Mux/Demux using 40G Optics

Answers in-line below.



If you  look at the CWDM Muxes (8 or 9 channel) you will notice a common
configuration of

    Upgrade Port (expansion port)  + 1450 or 1470 to 1610nm

    in the DWDM muxes you will see  them listed as # of Port + 1310 pass
thru channel.

These are exactly what you are looking for ..... :)