nanog mailing list archives

Re: Arista unqualified SFP


From: "Ryan, Spencer" <sryan () arbor net>
Date: Wed, 17 Aug 2016 19:52:51 +0000

Yes, email support and ask for the unlock code, they will make you agree that you know that 3rd party optics may 
explode the switch and it's not their fault.


The command they give you will have a key/hash built into it (but will work on any switch) that ties the "unlock" to 
your org.


Ours looks like this:


service unsupported-transceiver DescriptionOfKeyFromAristaGoesHere 0000000000 (hex key)


Spencer Ryan | Senior Systems Administrator | sryan () arbor net<mailto:sryan () arbor net>
Arbor Networks
+1.734.794.5033 (d) | +1.734.846.2053 (m)
www.arbornetworks.com<http://www.arbornetworks.com/>


________________________________
From: NANOG <nanog-bounces () nanog org> on behalf of Stanislaw <me () nek0 net>
Sent: Wednesday, August 17, 2016 3:50:12 PM
To: nanog () nanog org
Subject: Arista unqualified SFP

Hi all,
Is there a way for unlocking off-brand transceivers usage on Arista
switches?

I've got an Arista 7050QX switch with 4.14 EOS version. Then it has been
found out that Arista switches seem to not have possibility to unlock
off-brand xcievers usage (by some service command or so).

I've patched /usr/lib/python2.7/site-packages/XcvrAgent.py, made the
checking function bypass the actual check and it helped: ports are not
in errdisable state anymore. But despite of xceivers are detected
correctly, links aren't coming up (they are in notconnect state).

If anyone possibly have does have a sacred knowledge of bringing
off-branded transceivers to life on Arista switches, your help'd be very
appreciated. Thanks.


Current thread: