I have been troubleshooting an issue with Brocade TAC in regards to our Brocade CES that we use for some static 
routing.  The Firmware has been upgraded and hardware has been replaced and still the problem is occurring.  I have 
talked to some other carriers I work with that have previously used Brocade gear and switched because of odd issues 
that could not be resolved.  Curious if anyone on this list has had other odd Layer 3 issues with Brocade/Foundry 
Networks gear?  My issue seems to be somehow related to the table in memory that the ARP and next-hop entries are 
stored in, entries will point to the wrong mac address or the wrong port for the next-hop, it happens about every 60 
days like clockwork.

Jordan Hamilton
Telecommunications Engineer

Empire District Electric Co.
720 Schifferdecker
PO Box 127
Joplin, MO 64802

Ph:  417-625-4223
Cell:  417-388-3351


--
Note: To protect against computer viruses, e-mail programs may prevent sending or receiving certain types of file 
attachments.  Check your e-mail security settings to determine how attachments are handled.

--
This e-mail and any files transmitted with it are the property of THE EMPIRE DISTRICT ELECTRIC COMPANY, are 
confidential, and are intended solely for the use of the individual or entity to whom this email is addressed. If you 