nanog mailing list archives

Re: The Department of Work and Pensions, UK has an entire /8


From: Mark Andrews <marka () isc org>
Date: Thu, 20 Sep 2012 13:24:09 +1000


In message <505A8828.9040105 () dougbarton us>, Doug Barton writes:
On 09/19/2012 15:36, Joe Maimon wrote:
So 6-8 years to try and rehabilitate 240/4 was not even enough to try?

All the experts I consulted with told me that the effort to make this
workable on the big-I Internet, not to mention older private networks;
would be equivalent if not greater than the effort to deploy v6 ... and
obviously with much less long-term benefit.

Doug

And for those cases I would agree with you and the experts.

However it would have been possible to use 240/4 between CPE and a
6rd BR and CGN with CPE signaling that it can use 240/4 address it
is assigned one.  This could be done incrementally and would have
been better than the /10 that was eventually allocated for that
purpose.

Mark
-- 
Mark Andrews, ISC