Hi there,
I have the same problem in my network, I have GRE tunnel for transfering
users real internet traffic, they have problems with browsing websites like
yahoo.com or microsoft.com.
I had to set ip mtu 1500 to solve it, and it occurs fragmantation...
Thanks

On Mon, Oct 29, 2012 at 10:47 PM, Ray Soucy <rps () maine edu> wrote:

Sorry, glanced at this and thought it was someone having problems with
tunnel MTU without adjusting TCP MSS.

Nice work, though my preference is to avoid tunnels at all costs :-)




On Mon, Oct 29, 2012 at 12:39 PM, Templin, Fred L
<Fred.L.Templin () boeing com> wrote:
Hi Ray,

MSS rewriting has been well known and broadly applied for a long
time now, but only applies to TCP. The subject of MSS rewriting
comes up all the time in the IETF wg discussions, but has failed
to reach consensus as a long-term alternative.

Plus, MSS rewriting does no good for tunnels-within-tunnels. If
the innermost tunnel rewrites MSS to a value that *it* thinks is
safe there is no guarantee that the packets will fit within any
outer tunnels that occur further down the line.

What I want to get to is an indefinite tunnel MTU; i.e., admit
any packet into the tunnel regardless of its size then make any
necessary adaptations from within the tunnel. That is exactly
what SEAL does:

 https://datatracker.ietf.org/doc/draft-templin-intarea-seal/

Thanks - Fred
fred.l.templin () boeing com

-----Original Message-----
From: Ray Soucy [mailto:rps () maine edu]
Sent: Monday, October 29, 2012 7:55 AM
To: Templin, Fred L
Cc: Dobbins, Roland; NANOG list
Subject: Re: IP tunnel MTU

The core issue here is TCP MSS. PMTUD is a dynamic process for
adjusting MSS, but requires that ICMP be permitted to negotiate the
connection.  The realistic alternative, in a world that filters all
ICMP traffic, is to manually rewrite the MSS.  In IOS this can be
achieved via "ip tcp adjust-mss" and on Linux-based systems, netfilter
can be used to adjust MSS for example.

Keep in mind that the MSS will be smaller than your MTU.
Consider the following example:

 ip mtu 1480
 ip tcp adjust-mss 1440
 tunnel mode ipip

IP packets have 20 bytes of overhead, leaving 1480 bytes for data.  So
for an IP-in-IP tunnel, you'd set your MTU of your tunnel interface to
1480.  Subtract another 20 bytes for the tunneled IP header and 20
bytes (typical) for your TCP header and you're left with 1440 bytes
for data in a TCP connection.  So in this case we write the MSS as
1440.

I use IP-in-IP as an example because it's simple.  GRE tunnels can be
a little more complex.  While the GRE header is typically 4 bytes, it
can grow up to 16 bytes depending on options used.

So for a typical GRE tunnel (4 byte header), you would subtract 20
bytes for the IP header and 4 bytes for the GRE header from your base
MTU of 1500.  This would mean an MTU of 1476, and a TCP MMS of 1436.

Keep in mind that a TCP header can be up to 60 bytes in length, so you
may want to go higher than the typical 20 bytes for your MSS if you're
seeing problems.




On Tue, Oct 23, 2012 at 10:07 AM, Templin, Fred L
<Fred.L.Templin () boeing com> wrote:
Hi Roland,

-----Original Message-----
From: Dobbins, Roland [mailto:rdobbins () arbor net]
Sent: Monday, October 22, 2012 6:49 PM
To: NANOG list
Subject: Re: IP tunnel MTU


On Oct 23, 2012, at 5:24 AM, Templin, Fred L wrote:

Since tunnels always reduce the effective MTU seen by data packets
due
to the encapsulation overhead, the only two ways to accommodate
the tunnel MTU is either through the use of path MTU discovery or
through fragmentation and reassembly.

Actually, you can set your tunnel MTU manually.

For example, the typical MTU folks set for a GRE tunnel is 1476.

Yes; I was aware of this. But, what I want to get to is
setting the tunnel MTU to infinity.

This isn't a new issue; it's been around ever since tunneling
technologies
have been around, and tons have been written on this topic.  Look at
your
various router/switch vendor Web sites, archives of this list and
others,
etc.

Sure. I've written a fair amount about it too over the span
of the last ten years. What is new is that there is now a
solution near at hand.

So, it's been known about, dealt with, and documented for a long
time.
In
terms of doing something about it, the answer there is a) to allow
the
requisite ICMP for PMTU-D to work to/through any networks within your
span
of administrative control and b)

That does you no good if there is some other network further
beyond your span of administrative control that does not allow
the ICMP PTBs through. And, studies have shown this to be the
case in a non-trivial number of instances.

b) adjusting your own tunnel MTUs to
appropriate values based upon experimentation.

Adjust it down to what? 1280? Then, if your tunnel with the
adjusted MTU enters another tunnel with its own adjusted MTU
there is an MTU underflow that might not get reported if the
ICMP PTB messages are lost. An alternative is to use IP
fragmentation, but recent studies have shown that more and
more operators are unconditionally dropping IPv6 fragments
and IPv4 fragmentation is not an option due to wrapping IDs
at high data rates.

Nested tunnels-within-tunnels occur in operational scenarios
more and more, and adjusting the MTU for only one tunnel in
the nesting does you no good if there are other tunnels that
adjust their own MTUs.

Enterprise endpoint networks are notorious for blocking *all* ICMP
(as
well as TCP/53 DNS) at their edges due to 'security' misinformation
propagated by Confused Information Systems Security Professionals and
their ilk.  Be sure that your own network policies aren't part of the
problem affecting your userbase, as well as anyone else with a need
to
communicate with properties on your network via tunnels.

Again, all an operator can control is that which is within their
own administrative domain. That does no good for ICMPs that are
lost beyond their administrative domain.

Thanks - Fred
fred.l.templin () boeing com


-----------------------------------------------------------------------
Roland Dobbins <rdobbins () arbor net> // <http://www.arbornetworks.com


        Luck is the residue of opportunity and design.

                     -- John Milton






--
Ray Patrick Soucy
Network Engineer
University of Maine System

T: 207-561-3526
F: 207-561-3531

MaineREN, Maine's Research and Education Network
www.maineren.net



--
Ray Patrick Soucy
Network Engineer
University of Maine System

T: 207-561-3526
F: 207-561-3531

MaineREN, Maine's Research and Education Network
www.maineren.net




-- 
Regards,
Shahab Vahabzadeh, Network Engineer and System Administrator

Cell Phone: +1 (415) 871 0742