nanog mailing list archives

Re: Cost of fiber run between neighbouring office buildings


From: "Robert E. Seastrom" <rs () seastrom com>
Date: Tue, 02 Oct 2012 12:48:33 -0400


Second what Nick said.  Also, get quotes for double, quadruple, and
more of the number of fibers you think you need today.  If it makes
economic sense to leave strands unterminated (coil neatly in the
splice tray and have someone term later) by all means do it.  Extra
strands in the cable are almost free compared to the labor to pull it
in.

-r

Nick Hilliard <nick () foobar org> writes:

On 02/10/2012 13:35, Hank Disuko wrote:
 - 2 x 6-Strand 50/125u multimode, Tight Buffered, Armoured, Laser Ultra-Fox Fiber cables
 - Distance of run is approx 520 meters

For that length, go with single-mode.  10G-LR will happily run on 10km of
SMF, but 10G-SR flakes out at ~300m even on OM3.  Laying outdoor MMF plant
like this is totally pointless.  Using MMF for anything outside your
cabinet / small cage is creating a legacy deployment on day 1 which will
bite you in future years.

To answer the question you asked: if the ducts are already in place and
you're just pulling fibre through, you should have a breakdown in terms of
# of terminations + the manpower required to handle the pull + cable
finishing.  I.e. it shouldn't be very much.  If you need ducting laid or if
your existing ducting is in poor shape, that's a different issue.

Nick


Current thread: