nanog mailing list archives

re: AS path question.


From: "Nick Olsen" <nick () brevardwireless com>
Date: Wed, 10 Nov 2010 15:31:58 -0500

They are prepending routes.
Looks like both 43022 are prepending, As well as 47359...Multiple times... They do this to make that route look "bad" 
so it comes in other transit they have.

Nick Olsen
Network Operations
(855) FLSPEED  x106

----------------------------------------

From: "Greg Whynott" <Greg.Whynott () oicr on ca>
Sent: Wednesday, November 10, 2010 3:23 PM
To: "nanog () nanog org list" <nanog () nanog org>
Subject: AS path question.

Recently I adjusted the maxas-limit option on our router,    logs started reporting routes being refused because the AS 
path is to long.   seems to work as expected.

when I looked at the logs I was a bit confused at what i was looking at...   why is it there are multiple AS's in the 
path that appear to be the same AS?  I expected an AS path comprised of mostly unique ASs.

instead of this:

476330: Nov 10 14:55:07.247 EDT: %BGP-6-ASPATH: Long AS path 549 26677 6939 21011 43022 43022 43022 43022 43022 47359 
47359 47359 47359 47359 47359 47359 47359 received from isp router: More than configured MAXAS-LIMIT

i expected it would look more like:

476330: Nov 10 14:55:07.247 EDT: %BGP-6-ASPATH: Long AS path 549 26677 6939 21011 43022  47359 received from . .. .

thanks for your time again,
greg

--

This message and any attachments may contain confidential and/or privileged information for the sole use of the 
intended recipient. Any review or distribution by anyone other than the person for whom it was originally intended is 
strictly prohibited. If you have received this message in error, please contact the sender and delete all copies. 
Opinions, conclusions or other information contained in this message may not be that of the organization.



Current thread: