RE: rack power question
From: <michael.dillon () bt com>
Date: Tue, 25 Mar 2008 16:04:58 -0000
Or perhaps some non-conductive working fluid instead of water. That might not carry quite as much heat as water, but it would surely
carry more than air and if chosen correctly would have more benign
results
when the inevitable leaks and spills occur.
HCFC-123 is likely what would be used, which means that you would want to limit the amount of time that you spend inside the data center because, with the large number of connections in the facility, leaks will be inevitable and inhaling the gas causes liver damage. Essentially, you are saying that we should get rid of chillers and turn the entire data center into a giant chiller. Instead of being a building with rooms and equipment, the data center becomes a machine and humans only venture inside when the machine is shut down for maintenance.
Less practical but more fun to contemplate would be data centers
pressurized
with a working gas that offers better heat transfer than
oxygen/nitrogen and no
oxidation potential. Airlocks and suits for the techs, but no fire
worries ever.
Heck, just close the room and inject liquid nitrogen under the raised
floor to be
scavenged overhead and re-compressed, chilled, liquefied and sent
round again.
Reserve cooling for power outages is just huge dewars full of liquid
nitrogen :)
Not so serious today,
Why not? If you take your pressurized liquid nitrogen scenario and turn it inside out, then it might well be workable and there would be no need for suits. For instance, imagine a cylinder containing the liquid nitro cooling (liquid air might be cheaper) with devices attached all around like the petals on a flower. Each device has heat exchangers for cooling the hottest parts (CPUs) and the heat exchangers are attached to the cooling cylinder. With continued increase in density of cores, this could be feasible. In essence it would be a kind of blade server with the cooling and backplane in a central cylinder. Added benefits might come from supercooling the backplane. Consider what is happening beyond the consumer dual and 8-core (PS3) machines. <http://www.tilera.com/products/boards.php> <http://www.sicortex.com/architecture_tour> --Michael Dillon
Current thread:
- Re: rack power question, (continued)
- Re: rack power question Justin Shore (Mar 25)
- RE: rack power question Ben Butler (Mar 25)
- Re: rack power question Alexander Harrowell (Mar 25)
- RE: rack power question Ray Burkholder (Mar 25)
- RE: rack power question Alex Rubenstein (Mar 25)
- Re: rack power question Brian Raaen (Mar 25)
- Re: rack power question Marshall Eubanks (Mar 25)
- Re: rack power question Joel Jaeggli (Mar 25)
- Re: rack power question Leigh Porter (Mar 25)
- Re: rack power question Michael Holstein (Mar 25)
- RE: rack power question michael.dillon (Mar 25)
- Re: rack power question Tony Finch (Mar 26)
- Re: rack power question Deepak Jain (Mar 25)
- Re: rack power question Paul Vixie (Mar 25)
- Re: rack power question chuck goolsbee (Mar 25)
- Re: rack power question Petri Helenius (Mar 25)
- Re: rack power question Paul Vixie (Mar 25)
- Re: rack power question William Herrin (Mar 25)
- Re: rack power question Paul Vixie (Mar 25)
- Re: rack power question Petri Helenius (Mar 25)
- Re: rack power question Dorn Hetzel (Mar 26)