nanog mailing list archives

Re: IEEE 40GE & 100GE


From: "Robert E. Seastrom" <rs () seastrom com>
Date: Wed, 12 Dec 2007 08:05:38 -0500



"Justin M. Streiner" <streiner () cluebyfour org> writes:

I haven't read the draft spec yet to see what's being proposed for a
link budget at 3/4/10km, but that's just as important as the physical
distance.

That's a really good point, and one which I didn't originally consider
pre-coffee.  :-)

Link budget information on page 4, here:
http://www.ieee802.org/3/hssg/public/reach/Matsumoto_r1_1207.pdf
Relative cost estimates on page 5.

Suppositions for ingredients to link budget are here:
http://grouper.ieee.org/groups/802/3/hssg/public/nov07/cole_01_1107.pdf
(page 3)

I'm kind of looking longingly at that extra 3dB, given the slight
marginal extra cost and my knowledge of the trained chimp quality
mechanical splices that are rife in certain <cough> data centers.

                                        ---Rob



Current thread: