nanog mailing list archives

Re: Lucent GBE (4 x VC4) clues needed


From: Saku Ytti <saku+nanog () ytti fi>
Date: Wed, 15 Nov 2006 12:25:07 +0200


Consider this topology

GSR - 3750 --(GE over 4xVC4) - NSE100 - NSE100 --(GE over 4xVC4) -- 3550 - GSR

This should have been Nortel GBE, not Lucent my bad.

My first best guess was right, it was lucent system after all.

We've now solved the issue, problem is in GBE card in Lucent in
hardware revision S1:7, which is broken by design. S1:3, S1:6
work and we should be able to test S1:8 soon, but we expect
it to work also.

Symptoms were that it flipped bits (but not randomly, just
couldn't figure out why certain places saw bit flips) and
calculated new, correct CRC to the ethernet frame, after
it had flipped bit.

-- 
  ++ytti