The cabling arrangement is:

Foundry -- Straight -- Patch -- Underfloor -- Patch -- Crossover -- Cisco
  GBIC       Cable      Panel     Straight     Panel      Cable

If I replace the final crossover cable with a straight,
Just do that ^^^ and give it a try.

Will do.


Having done a bit more looking into this myself, one thing that might be
a cause is the cross-over, in the sense that if it is a 100BASE-T
crossover, only two of the pairs will be crossed, and the other two
pairs are usually wired straight.

A GigE cross over, assuming you need one if you're ports don't support
automatic cross over, has all four pairs crossed over
(1-3,2-6,3-1,6-2,4-7,5-8,7-4,8-5). My guess would be that if a device
only detects two of the four pairs crossed, it drops back to 100BASE-T.
In other words, GigE cross overs are backwards compatible with
10/100BASE-T, but 10/100BASE-T crossovers aren't forward compatible with
GigE.

A GigE rated straight through path would be the first thing I'd test,
after that, possibly try a GigE crossover somewhere between the devices.