Hi,We're looking at doing outbound traffic values based on upstream ("tier1") MED values. But, of course, there's no standard for MED values. Assuming I can get definations from the upstreams as to what their MED values mean, I have to rebase them into a common range.
However, a route-map (cisco, foundry) only allows you to set, add or subtract to an MED value, so this doesn't seem possible.
Is anyone doing this, and if so how? Sam
Current thread:
- Utilising upstream MED values Sam Stickland (Mar 18)
- Re: Utilising upstream MED values Alexander Koch (Mar 19)
- <Possible follow-ups>
- RE: Utilising upstream MED values Howard, W. Lee (Mar 19)