nanog mailing list archives

Utilising upstream MED values


From: Sam Stickland <sam_ml () spacething org>
Date: Fri, 18 Mar 2005 14:05:12 +0000 (GMT Standard Time)


Hi,

We're looking at doing outbound traffic values based on upstream ("tier1") MED values. But, of course, there's no standard for MED values. Assuming I can get definations from the upstreams as to what their MED values mean, I have to rebase them into a common range.

However, a route-map (cisco, foundry) only allows you to set, add or subtract to an MED value, so this doesn't seem possible.

Is anyone doing this, and if so how?

Sam