Re: Cisco 4000 series switches


From: "J.J. Guy" <jjg () cwru edu>
Date: Wed, 17 Jul 2002 21:28:42 -0500


I've seen the same behavior with a Catalyst 2948G.   My servers weren't
experiencing any problems, and appeared to be connecting at 100/Full -
despite what the Fluke reports.  If I recall correctly, the 2948s use the
same software base as the 4000s - I've written it off as a software
incompatibility between the 2948/4000 code and the Fluke.

I did a cursory search of Cisco's bug reports, but found nothing related.

My advice is to ignore the auto-negotiate between the 4000 and the Fluke.

J.J.


From: Joes Jobs <joej () mail rocknyou com>
Date: Tue, 16 Jul 2002 03:56:22 -0700
To: nanog () merit edu
Subject: Cisco 4000 series switches
<snip>
However the line analyzer says duplex is half, but advertised full.
When I set the node in question to Half Duplex, the switch reports half duplex
as well.