nanog mailing list archives

Re: [nsp] Cisco DS3 Questions..


From: Jesper Skriver <jesper () skriver dk>
Date: Mon, 25 Feb 2002 19:16:43 +0100


On Mon, Feb 25, 2002 at 07:36:11AM -0800, Eliot Lear wrote:

At 09:24 PM 2/22/2002 +0100, Jesper Skriver wrote:

int Serial0
 encap hdlc
 down-when-looped

I know, but that needs to be configued in both ends, and as it's not the
default, it's likely not to be configured on the CPE device ...

Neither is PPP.

The customer will never get the link up if he/she doesn't
configure PPP, he/she will get link up if the link is configured
for HDLC but they havn't configured 'down-when-looped'

/Jesper

-- 
Jesper Skriver, jesper(at)skriver(dot)dk  -  CCIE #5456
Work:    Network manager   @ AS3292 (Tele Danmark DataNetworks)
Private: FreeBSD committer @ AS2109 (A much smaller network ;-)

One Unix to rule them all, One Resolver to find them,
One IP to bring them all and in the zone to bind them.