nanog mailing list archives

Re: More 6509 problems...


From: Rodney Dunn <rodunn () cisco com>
Date: Thu, 1 Feb 2001 18:21:48 -0500


Danny,

The interface status should be independent of
the swithcing path.  I've never seen the line
state be affected by the switching mechanism
(although I have seen the opposite).

Can you email me the case# you had so I can take 
a look?

rodney


On Tue, Jan 30, 2001 at 02:22:21PM -0600, Danny Snyder wrote:

Ya got me on that one....Cisco didn't really say why and I didn't think to
ask them either....

--Danny




-----Original Message-----
From: Kenny Sallee [mailto:k_sallee () yahoo com]
Sent: Tuesday, January 30, 2001 11:28 AM
To: agudgeon () firstnet co uk; 'Danny Snyder'
Cc: nanog () merit edu
Subject: Re: More 6509 problems...


How would CEF cause an interface to be up/down?  Just curious....Kenny

----- Original Message -----
From: "Alison Gudgeon" <agudgeon () firstnet co uk>
To: "'Danny Snyder'" <dsnyder () nowdocs com>; <nanog () merit edu>
Sent: Tuesday, January 30, 2001 8:36 AM
Subject: RE: More 6509 problems...



Hi

Hybrid IOS

I've got IP CEF DISTRIBUTED set globally.  Did you have it enabled or
disabled on the T3 interface?

Ali

-----Original Message-----
From: Danny Snyder [mailto:dsnyder () nowdocs com]
Sent: 30 January 2001 16:21
To: agudgeon () firstnet co uk; nanog () merit edu
Subject: RE: More 6509 problems...


Alison,

I've had VERY similar problems with a 6509 (Sup 1a + MSFC2) with a FlexWAN
and a PA-2T3+.  After spending the better part of two weeks on the phone
with Cisco, we finally determined that ip cef distributed needed to be
turned on in global configuration.

Also, are you running native IOS or Catalyst OS on the Supervisor and IOS
on
the MSFC ?

Danny Snyder
Network Administrator
NowDocs, Inc.




-----Original Message-----
From: owner-nanog () merit edu [mailto:owner-nanog () merit edu]On Behalf Of
Alison Gudgeon
Sent: Tuesday, January 30, 2001 10:18 AM
To: nanog () merit edu
Subject: More 6509 problems...



Hi,

Is anyone doing the following:

6509 (supervisor 1a + msfc) - with a flexWAN adapter to take a Packet Over
Sonet OC-3 card.

I'm having great problems getting up/up on the interface, the current
situation is up/down, a hardware loop at the telco kit brings the line
up/up
but otherwise just up/down.  Config is default I've just put IP's on.

I'm running very new code - 12.1(4)E1

many thanks in advance for any help.


Kind Regards


Alison





Current thread: