Re: issue: SMB2: The value of "Fixed Part Length" seems wrong
From: Alexis La Goutte <alexis.lagoutte () gmail com>
Date: Tue, 24 Sep 2019 14:28:41 +0200
Hi Zhai, Can you open a issue on bug tracker and a pcap ? https://bugs.wireshark.org You can also push a fix directly on Gerrit https://code.wireshark.org/review and look for help https://wiki.wireshark.org/Development/SubmittingPatches Cheers On Tue, Sep 24, 2019 at 1:06 PM Xuan k <kxuanobj () gmail com> wrote:
Hi everyone, I found a issue about SMB2 protocol. The wireshark gives a wrong value on "Fixed Part Length" field. This is a Close Request message: Close Request (0x06) StructureSize: 0x0018 0000 0000 0001 100. = Fixed Part Length: 12 .... .... .... ...0 = Dynamic Part: False Close Flags: 0x0000 GUID handle File: Templates But the "Fixed Part Length" should be 24 in this message, not 12. It seems that the problem is caused by misusing the bit mask of struct header_field_info. The source line epan/dissectors/packet-smb2.c:10984 use a mask 0xFFFE to filter out the field. 10982 { &hf_smb2_buffer_code_len, 10983 { "Fixed Part Length", "smb2.buffer_code.length", FT_UINT16, BASE_DEC, 10984 NULL, 0xFFFE, "Length of fixed portion of PDU", HFILL } 10985 }, But in function `proto_tree_set_uint` (epan/proto.c:5281), it shifts the numberic, and cause the numberic been divided by 2. hope this issue will be resolved soon. Thanks, Zhai Zhaoxuan
___________________________________________________________________________ Sent via: Wireshark-dev mailing list <wireshark-dev () wireshark org> Archives: https://www.wireshark.org/lists/wireshark-dev Unsubscribe: https://www.wireshark.org/mailman/options/wireshark-dev mailto:wireshark-dev-request () wireshark org?subject=unsubscribe
Current thread:
- issue: SMB2: The value of "Fixed Part Length" seems wrong Xuan k (Sep 24)
- Re: issue: SMB2: The value of "Fixed Part Length" seems wrong Alexis La Goutte (Sep 24)