Hello Folks, I was able to configure snort for multiple sensors on same database just ran snort for each sensor "snort -c ... -i eth0 " "snort -c ... -i eth1 " ... and things worked out fine happy weekend to all Best Regards, Salil. On Fri, 25 Mar 2005 Salil D. wrote :
Hello Michael, I still am not able to configure additional sensors. Following line is from my snort.conf file, " output database: log, mysql, encoding=ascii user=XXXXXXX password=XXXXXX dbname=snort host=XXX.XXX.XXX.XXX " I have total 3 interface cards on the machine where snort is installed (all cards on same machine) snort has detected one ip address out of the 3 , and set that as default sensor name. In order to configure additional sensor, I have explicitly inserted a record in the sensor table with relevant field entries for other ip address. Logged data carries information only about the default sensor. I dont find any data sensed at the other sensor inserted later. am I headed in the right way? Kindly let me know of possible solution. Thanks, Salil.
Current thread:
- Multiple Sensors Salil D. (Mar 24)
- Re: Multiple Sensors Frank Knobbe (Mar 25)
- <Possible follow-ups>
- Re: Multiple Sensors Salil D. (Mar 25)