nanog mailing list archives

Re: DWDM Mux/Demux using 40G Optics


From: Colton Conor <colton.conor () gmail com>
Date: Mon, 19 Jun 2017 15:46:41 -0500

Luke,

I agree, I would be talking about getting one with the 1310NM special port
for the QSFP+ input that emitts 1270-1330nm light, and then say 4 client
ports on different channels than that light range.

On Mon, Jun 19, 2017 at 3:40 PM, Luke Guillory <lguillory () reservetele com>
wrote:

If their 1310 passes them I would have to think you can't use is with
other client ports that would fall within the window. Here is a graph
showing those 4 for the 40g it seems.

http://public-wordpress-kkc.s3.amazonaws.com/wp-content/
uploads/2014/07/Graph1.jpg



-----Original Message-----
From: NANOG [mailto:nanog-bounces+lguillory=reservetele.com () nanog org] On
Behalf Of Colton Conor
Sent: Monday, June 19, 2017 3:32 PM
To: Mike Hammett
Cc: nanog list
Subject: Re: DWDM Mux/Demux using 40G Optics

I guess that makes sense. The plus or minus some is the question. FS is
claiming their 1310 port support QSFP+, which is 1270, 1290, 1310, and 1330
combined. I understand you can us 1310, but I am still scratching my head
as to how they all one minus and two above 1310 to work. Of course they
don't have any datasheets to show the range either.



On Mon, Jun 19, 2017 at 3:17 PM, Mike Hammett <nanog () ics-il net> wrote:

I'd imagine they vary based on vendor, so you'd have to check with the
specific vendor in terms of absolute technical specifications.

A 1310 and 1550 port only allow those channels plus or minus some,
manufacturer dependent.
An expansion port passes everything not used by that device.

Some manufacturers are even configurable pre-order, so you could get
exactly what you needed (other than multiple 40G channels).




-----
Mike Hammett
Intelligent Computing Solutions
http://www.ics-il.com

Midwest-IX
http://www.midwest-ix.com

----- Original Message -----

From: "Colton Conor" <colton.conor () gmail com>
To: "Faisal Imtiaz" <faisal () snappytelecom net>
Cc: "Mike Hammett" <nanog () ics-il net>, "Luke Guillory" <
lguillory () reservetele com>, "nanog list" <nanog () nanog org>
Sent: Monday, June 19, 2017 3:14:19 PM
Subject: Re: DWDM Mux/Demux using 40G Optics


Thanks for the answers. From the sounds of it, no one knows the real
difference between the expansion port, 1310 port, and 1550 port. For
real world applications, I would assume the monitor port would be to
plug in a handheld meter, and see which channels are coming through
that node without breaking the ring. Not sure if their would be a
monitor port for both directions is you were using a OADM?


On Mon, Jun 19, 2017 at 2:38 PM, Faisal Imtiaz <
faisal () snappytelecom net
wrote:





Answers in-line ...


Faisal Imtiaz
Snappy Internet & Telecom
7266 SW 48 Street
Miami, FL 33155
Tel: 305 663 5518 x 232

Help-desk: (305)663-5518 Option 2 or Email: Support () Snappytelecom net




<blockquote>
From: "Colton Conor" < colton.conor () gmail com >
To: "Mike Hammett" < nanog () ics-il net >
Cc: "Luke Guillory" < lguillory () reservetele com >, "nanog list" <
nanog () nanog org >, "Faisal Imtiaz" < faisal () snappytelecom net >
Sent: Monday, June 19, 2017 3:30:37 PM
Subject: Re: DWDM Mux/Demux using 40G Optics




<blockquote>

I guess that is the real question. Besides the client ports that are
clearly identified by channel number on Muxes, what channels can the
special ports handle?

http://www.fs.com/products/43723.html It has 4 special service port
options:

1. Expansion Port (Based on what I am seeing, I think this would be to
stack another mux if you needed more channels. So I assume it allows
all channels to be added besides the client channels?) </blockquote>



Exactly... this is basically a pass thru port, i.e. what is not
getting mux/demux should get passed thru (keep the insertion loss in
mind).


<blockquote>


2. Monitor Port (I think this is just a tap that you would hook a
monitor up to, and be able to see all channels coming through with a
meter. I assume not a good idea to add/drop channels through this port)?
</blockquote>



I don't use this port, but supposedly it will pass a fraction 5% of
the light from the main port so that it can be monitored. May be
someone else can offer some practical use for this port.
<blockquote>


3. 1310nm Port (Labeled as 1310, but clearly allows more than just
1310 since tutorial is saying it supports QSFP+ which is 1270 - 1330
nm, so what range does it really support or is there no a range?)
</blockquote>

Not sure about the range question, but this is the port for having the
40g/100g QSFP+ pass thru


<blockquote>


4. 1550nm Port (Labeled as 1550nm, but I wonder if its like the
1330nm?)


</blockquote>

I have not had the need to explore this in detail, but from my initial
understanding, this can be used for ZR (long range optics) and or to
stack a DWDM Mux


<blockquote>


Would you recommend a monitor port on every mux you buy?


</blockquote>

As I shared above, I don't.




<blockquote>



On Mon, Jun 19, 2017 at 2:18 PM, Mike Hammett < nanog () ics-il net >
wrote:

<blockquote>


Verify pass-through frequencies for the 1310 (or equivalent) for the
passive mux in question. This would only work for a single channel.




-----
Mike Hammett
Intelligent Computing Solutions
http://www.ics-il.com

Midwest-IX
http://www.midwest-ix.com



From: "Luke Guillory" < lguillory () reservetele com >
To: "Faisal Imtiaz" < faisal () snappytelecom net >, "Colton Conor" <
colton.conor () gmail com >
Cc: "nanog list" < nanog () nanog org >
Sent: Monday, June 19, 2017 2:13:10 PM
Subject: RE: DWDM Mux/Demux using 40G Optics



Faisal,

How would he inject his current 4x10 40g into the mux which is
currently on a single LC cable?





Luke Guillory
Network Operations Manager

Tel: 985.536.1212
Fax: 985.536.0300
Email: lguillory () reservetele com

Reserve Telecommunications
100 RTC Dr
Reserve, LA 70084

____________________________________________________________
_____________________________________

Disclaimer:
The information transmitted, including attachments, is intended only
for the person(s) or entity to which it is addressed and may contain
confidential and/or privileged material which should not disseminate,
distribute or be copied. Please notify Luke Guillory immediately by
e-mail if you have received this e-mail by mistake and delete this
e-mail from your system. E-mail transmission cannot be guaranteed to
be secure or error-free as information could be intercepted,
corrupted, lost, destroyed, arrive late or incomplete, or contain
viruses. Luke Guillory therefore does not accept liability for any
errors or omissions in the contents of this message, which arise as a
result of e-mail transmission. .

-----Original Message-----
From: NANOG [mailto: nanog-bounces () nanog org ] On Behalf Of Faisal
Imtiaz
Sent: Monday, June 19, 2017 2:02 PM
To: Colton Conor
Cc: nanog list
Subject: Re: DWDM Mux/Demux using 40G Optics

Answers in-line below.



If you look at the CWDM Muxes (8 or 9 channel) you will notice a
common configuration of

Upgrade Port (expansion port) + 1450 or 1470 to 1610nm

in the DWDM muxes you will see them listed as # of Port + 1310 pass
thru channel.

These are exactly what you are looking for ..... :)



</blockquote>