nanog mailing list archives
Re: A9K-MPA-20X1GE in ASR9001
From: Nikolay Shopik <shopik () inblock ru>
Date: Fri, 25 Oct 2013 14:05:27 +0400
I don't have any GBIC/SPF inserted in it right now, it just turn off whole module. So won't allow me even fpd upgrade. On 25/10/13 14:02, Ray Ludendorff wrote:
It means that you did not purchase a original Cisco GBIC for the interface .. Therefore it will not be TAC supported if you have problems with the interface. There is a command to override this error and still use the interfaces. Sent from mobile deviceOn Oct 25, 2013, at 11:56, "Nikolay Shopik" <shopik () inblock ru> wrote: Hey, anyone had issues with A9K-MPA-20X1GE in ASR9001? It get disabled for us after 20 seconds finishing initialization, with such message. %PLATFORM-SCC-2-BAD_ID_HW : Failed Identification Test in 0/130/0 [1/0] The module in 0/130/0 in this router may not be a genuineCisco product.
Current thread:
- A9K-MPA-20X1GE in ASR9001 Nikolay Shopik (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Remco Bressers (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Nikolay Shopik (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Bill Woodcock (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Ahad Aboss (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Nikolay Shopik (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Bill Woodcock (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Bill Woodcock (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Nikolay Shopik (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Remco Bressers (Oct 25)
- Re: A9K-MPA-20X1GE in ASR9001 Xu Hu (Oct 27)
- <Possible follow-ups>
- Re: A9K-MPA-20X1GE in ASR9001 Nikolay Shopik (Oct 25)
- A9K-MPA-20X1GE in ASR9001 Julian Eble (Oct 25)