nanog mailing list archives

Re: traffic accounting


From: Mark Tees <marktees () gmail com>
Date: Wed, 13 Mar 2013 08:14:23 +1100

I guess if you are only counting bytes is possible to use firewall filters with counters? I guess it depends on how 
many match conditions vs lookup time are acceptable?

Sent from some sort of iDevice.

On 13/03/2013, at 2:18 AM, "Dobbins, Roland" <rdobbins () arbor net> wrote:


On Mar 12, 2013, at 8:53 PM, Joe Abley wrote:

Can you use cflow/jflow/ipfix exports with 1:1 sampling on an MX480 without an MS-DPC?

I'm not a Juniper person, so I'm not sure; note however that a) MS-DPC is necessary for NetFlow v9 (which is required 
for IPv6, for example), and b) sampled NetFlow (i.e., not 1:1, but higher ratios) is widely used and accepted in the 
industry.

-----------------------------------------------------------------------
Roland Dobbins <rdobbins () arbor net> // <http://www.arbornetworks.com>

     Luck is the residue of opportunity and design.

              -- John Milton