nanog mailing list archives

Re: Comcast Ethernet Feed


From: Brielle Bruns <bruns () 2mbit com>
Date: Thu, 29 Mar 2012 19:42:11 -0600

On 3/29/12 7:32 PM, Brian R. Watters wrote:
Your correct with your understanding of our setup, I also note on our
NPE-G1 that the onboard GIGE interface will auto-negotiation and I do
see the flow control is not supported via the other side (Comcast)
but as soon as I refresh and view the GIG# interface again I note
that flow control is turned back on and "no negotiation auto" is back
on the interface cfg ?, this is certainly part of the issue .. is
their a way to disable flow control on the onboard GIGE ?  .. as
stated Comcast does not want flow control on.

Yes there are other ports on this router that perform without issue
and as designed both other GIGE interfaces that are VLAN'ed and
Serial interfaces that are both DS3 and a PA-4T bonded to 6MEG's.


How do you have the PA modules installed? Layout can make a huge difference on those given the bandwidth points system.

http://www.cisco.com/en/US/docs/routers/7200/configuration/7200_port_adapter_config_guidelines/3875In.html#wp1061412



--
Brielle Bruns
The Summit Open Source Development Group
http://www.sosdg.org    /     http://www.ahbl.org


Current thread: