nanog mailing list archives

Re: How to loadshare over many E1 links


From: Leo Bicknell <bicknell () dimension net>
Date: Fri, 18 Sep 1998 11:56:04 -0400 (EDT)

In article <19980918095708.B10051 () skriver dk> you write:
How would you loadshare over many (>6) parallel E1 links. Currently we
do it by connecting them directly to the Cisco's in each end, and do
CEF based per-packet loadsharing, it works fine, but support a max of
6 E1's ...

        Cisco has a nice white paper on this:
http://www.cisco.com/warp/public/733/adap/multi/althb_wp.htm

        I think Multilink PPP may be your answer, as it goes
up to 8 links.  There is a CPU hit though, I've never tried
Multilink on a high speed interface so I don't know how bad
it might affect the router.

-- 
Leo Bicknell - bicknell () dimension net
Network Engineer (CCIE #3440) - Dimension Enterprises
1-703-709-7500, fax, 1-703-709-7699


Current thread: