nanog mailing list archives
Re: MAE West
From: Dave Crocker <dcrocker () brandenburg com>
Date: Mon, 14 Jul 1997 00:01:30 -0700
At 11:38 PM 7/13/97 -0700, Stephen Stuart wrote:
As Lance Tatman pointed out, load-balancing only works between circuits joining the same two switches. This would certainly be a factor in planning what kind of wide-area connectivity to use to join two groups of switches. A single 400Mb/s aggregate might perform much better than a pair of 200Mb/s aggregates.
Better performance, but worse reliability? The single 400Mb/s is, after all, a single point of failure, no? d/
Current thread:
- MAE West Rodney Joffe (Jul 11)
- Re: MAE West Lance Tatman (Jul 11)
- Re: MAE West Steve Feldman (Jul 11)
- Re: MAE West Jay R. Ashworth (Jul 11)
- Re: MAE West Owen DeLong (Jul 13)
- Re: MAE West Stephen Stuart (Jul 13)
- Re: MAE West Dave Crocker (Jul 14)
- Re: MAE West Bill Manning (Jul 14)
- Re: MAE West Owen DeLong (Jul 14)
- Message not available
- Re: MAE West Jay R. Ashworth (Jul 14)
- Re: MAE West Stephen Stuart (Jul 14)
- Re: MAE West bmanning (Jul 14)
- Re: MAE West Wayne Bouchard (Jul 14)
- Message not available
- Re: MAE West Jay R. Ashworth (Jul 14)
- Re: MAE West Stephen Stuart (Jul 14)
- Message not available
- Re: MAE West Jay R. Ashworth (Jul 14)
- Re: MAE West Stephen Stuart (Jul 14)