Bugtraq mailing list archives
Re: Siemens *35 and 45 series phones SMS Danial of Service
From: Jan Niehusmann <jan () gondor com>
Date: Mon, 3 Mar 2003 23:46:09 +0100
On Mon, Mar 03, 2003 at 01:06:43AM -0000, subj subj wrote:
To vulnerability are subject: All versions siemens *35 and *45.
[...]
languages from the phone language selection menu, will completely disable *35 series phones and result in a 2 minute read delay on *45 series phones. Note that
Please note that this vulnerability isn't as serious as you describe it. At least on my S45, I am able to interrupt this 2 minute delay at any time by pressing the 'hang up' key (but I have to press it for about half a second instead of just hitting it), the message can be read by using 'edit message' instead of 'read message', and it can be deleted without problems. So while this obviously is a bug, it can hardly be called a DoS. Jan
Attachment:
_bin
Description:
Current thread:
- Siemens *35 and 45 series phones SMS Danial of Service subj subj (Mar 03)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Jan Niehusmann (Mar 03)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Andreas Hofmeister (Mar 04)
- Re[2]: Siemens *35 and 45 series phones SMS Danial of Service João Colaço (Mar 04)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Robert Waldner (Mar 04)
- RE: Siemens *35 and 45 series phones SMS Danial of Service Dawid Szymański (Mar 05)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Andreas Hofmeister (Mar 04)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Christian "cycloon" Gut (Mar 05)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Lukasz Wojcik (Mar 06)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Timothy Farrell (Mar 06)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Luciano Miguel Ferreira Rocha (Mar 06)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Raymond A. Meijer (Mar 06)
- <Possible follow-ups>
- RE: Siemens *35 and 45 series phones SMS Danial of Service Willis Johnson (Mar 04)
(Thread continues...)
- Re: Siemens *35 and 45 series phones SMS Danial of Service Jan Niehusmann (Mar 03)